CET3-AR-CRA-AH-50X-SG Công tắc an toàn EUCHNER VIỆT NAM
GIỚI THIỆU CET3-AR-CRA-AH-50X-SG Công tắc an toàn EUCHNER VIỆT NAM
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 6500 N
- Up to 20 switches in series
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Category 4 / PL e according to EN ISO 13849-1
- With 2 plug connectors M12
- Unicode
- Door monitoring output
- Indication of the door position by LED
- Teach-in input
- Approach direction A (delivery state)
Workspace
Repeat accuracy R | |
according to EN 60947-5-2 | 10 % |
Electrical connection values
Fuse | |
external (operating voltage UB) | 0.25 … 8 A |
external (solenoid operating voltage UCM) | 0.5 … 8 A |
Power consumption | |
Solenoid | 11 W |
Connecting cable | 30V DC, 2A |
Operating voltage DC | |
LED | 24 V DC -15% V DC … +10% V DC |
UB | 24 V DC -15% … +15% reverse polarity protected, regulated, residual ripple<5%, PELV |
EMC protection requirements | Acc. to EN IEC 60947-5-3 |
Utilization category | |
DC-13 | 24 V 200 mA |
Solenoid operating voltage DC | |
UCM | 24 V DC -15% … +10% reverse polarity protected, regulated, residual ripple<5%, PELV |
Solenoid duty cycle | 100 % |
Risk time according to EN 60947-5-3 | max. 400 ms |
Risk time according to EN 60947-5-3, extension for each additional device | max. 5 ms |
Switching load | |
according to UL | 24V DC, Class 2 |
Safety class | |
EN IEC 61140 | III |
Current consumption | |
IB | 80 mA |
ICM | 450 mA |
Test pulse duration | max. 1 ms |
Degree of contamination (external, according to EN 60947-1) | 3 |
Teach-in input | |
Input voltage | |
LOW | 0 … 1 V DC |
HIGH | 15 … 27.6 V DC |
Monitoring output OUT D | |
Output type | p-switching, short circuit-proof |
Output voltage | |
OUT D | 0.8xUB … UB V DC |
Switching current | |
OUT D | 1 … 50 mA |
Switching delay from state change | max. 700 ms |
Monitoring output OUT | |
Output type | p-switching, short circuit-proof |
Output voltage | |
OUT | 0.8xUB … UB V DC |
Switching current | |
OUT | 1 … 50 mA |
Switching delay from state change | max. 400 ms |
Safety outputs OA / OB | |
Output type | 2 semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
HIGH U(OA,OB) | UB-1.5V … UB V DC |
LOW U(OA,OB) | 0 … 1 V DC |
Discrepancy time | |
both safety outputs | max. 10 ms |
Turn-on time | 400 ms |
Off-state current Ir | max. 0.25 mA |
Risk time according to EN 60947-5-3 | |
Single device | |
Switching current | |
per safety output OA / OB | 1 … 200 mA |
Mechanical values and environment
Approach speed | max. 20 m/min |
Connection type | 2 plug connectors M12, 5- and 8-pin |
Ready delay | 10 s |
Installation orientation | any |
Switching frequency | max. 0.5 Hz |
Degree of freedom X | ±5 mm |
Degree of freedom Y | ±5 mm |
Degree of freedom Z | ±4 mm |
Mechanical life | 2 x 10⁶ |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP67 |
Ambient temperature | |
with UB = 24 V DC | -20 … +55 °C |
Material | |
Safety switch housing | Die-cast aluminum |
Ramp | Stainless steel |
Locking force Fmax | 6500 N |
Locking force FZh | 5000 N |
Guard locking principle | Closed-circuit current principle |
Đánh giá